AAI ORIGINAL English Verison N1201SA N1201SA+ 34.375MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester
83
Baweriya ewle a checkout

Tiştên vegerê dê di nav 40 rojan de were qebûl kirin dema ku roja wergirtina malê ye. Tiştên xweser nayên vegerandin an guhertin. Tiştên ku bi karta diyariya elektronîkî hatine kirin tenê dikarin were guhertin; veger nayê sepandin.
Diyariya belaş
Bi xêr hatî Roymall, malpera weya pîşeyî ji bo kirîna diyariyên depoya departmanê ya premium. Em piştgirî û qedirgirîya we bilind dikin û em dixwazin spasiya xwe bi zêdekirina hêvîya kêfê ya kirînên we nîşan bidin. Dema ku hûn li vir dikirin, hûn ne tenê hilberên kalîteya bilind ên ku jiyana we baştir dikin bistînin, lê hûn ê diyariyek belaş a taybetî jî bi her fermanê bistînin. Amade ne ku koleksiyona me vedikin û diyariyên we yên bêkêmasî bibînin? Di navbijartina me ya hilberên depoya departmanê ya premium bigerin, fermanê bidin û paşê li benda diyariya belaş a we ya bi kirîna we re were.Polîtîkaya barkirinê
Em ê piştî wergirtina fermanên we ji bo şandina tiştan bi xebatê bigirin û pê ewle bin ku ew bi ewlehî têne. Agahiyên şandinê dê di e-nameya weya pejirandinê de were dayîn.Di piraniya rewşan de, ferman di nav 2 rojan de têne sepandin.Di şert û mercên taybetî de, wê wiha dereng bibin: Dema ku hûn fermanê di şemî, yekşem an jî înên giştî de bidin, dê 2 roj dereng bibin.Normal, ew hewce dike 5-7 rojên kar (ji duşemê heta înê) bêyî ku ji hêla derengiya firînê an faktorên din yên hawîrdorê ve were bandor kirin.Ji ber ku karûbara meya şandinê li seranserê cîhanê ye, ji ber vê yekê dema şandinê dê li gor cihê we be, ji ber vê yekê heke hûn li navçeyên dûr an welatan in, hûn hewce ne ku hinekî bisekinin.1. Polîtîkaya Vegerê & Guhertinê
Em tenê tiştên ku ji roymall.com hatine kirin qebûl dikin. Heke hûn ji belavkerên me yên herêmî an firoşgehên din bikirin, hûn nikarin wan li vir vegerînin. Tiştên firotanê yên dawî an diyariyên belaş ji bo vegerê nayên qebûl kirin. Ji bo mafdarî ji bo vegerê, tişta we divê nehatiye bikar anîn û di heman rewşê de be ku hûn wê wergirtiye. Divê ew di pakêta xweya orîjînal de jî be.Piştî ku hûn rêwerzên vegerê ji me wergirtin, ji kerema xwe tiştên xwe yên vegerandî pakêj bikin û pakêta xwe li postexaneya herêmî an kuryeyek din bihêlin.Em ê tiştên we yên vegerandî an guhartî di nav 3-5 rojên karkirinê de piştî ku em wê wergirin, bisekinin. Veger dê bixweber li ser rêbaza weya orîjînal a dayînê were kredî kirin.Tiştên ku bi awayekî xweser hatine çêkirin, di nav de mezinahiya xweser, rengê xweser, an çapa xweser, nayên vegerandin an guhertin.Heke hûn hewceyê alîkariyê bin, ji kerema xwe bi me re têkilî daynin. service@roymall.com an Whatsapp: +86193598494712.Polîtîkaya Vegerê
Hûn ê piştî ku em pakêta vegerandî wergirin û kontrol bikin, vegerê tevahî an 100% krediya dikanê bistînin. Veger dê bixweber li ser rêbaza weya orîjînal a dayînê were kredî kirin. Ji kerema xwe bînin ku lêçûnên barkirinê û her qebzeyek an xerc nayê vegerandin. Lêçûnên zêde yên barkirinê piştî ku pakêt hat şandin, nayê vegerandin. Hûn berpirsiyar in ku hûn van lêçûnan bidin û em nikarin wan bêpar bikin an vegerînin, heta ku ferman ji me re were vegerandin.Heke pirsgirêkek bi prosesa vegerê hebe, ji kerema xwe bi me re têkilî daynin. service@roymall.com an Whatsapp: +8619359849471
Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual
Tools, Industrial & Scientific Ranking
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter